Barrier Gate Dual Channel Loop Sensor | High Accuracy & Wide Temp Range & Direction Logic
The JUTAI Barrier Gate Dual Channel Loop Sensor (Models LD-200/LD-202) is engineered to deliver unmatched precision and reliability for automated barrier systems in high-traffic environments. Featuring dual-channel independent control, it ensures high-accuracy vehicle detection with 16-level sensitivity adjustment (0-F) across a 20–2000μH inductance range, capturing everything from motorcycles to heavy trucks. The sensor’s advanced direction logic utilizes time-sequence analysis to determine vehicle entry/exit direction with <1-second latency, enabling intelligent barrier control in parking lots, toll lanes, and secure facilities. Built to endure extreme conditions, the IP67-rated aluminum housing operates flawlessly in a -40°C to +70°C temperature range, resisting dust, moisture, and corrosive elements for year-round reliability.
In smart parking systems, the LD-202’s direction logic prevents tailgating by triggering barrier closure only after confirming vehicle clearance, while Channel 1 ensures rapid gate opening (≤10ms response). For industrial gate control, the sensor’s wide temperature tolerance maintains stable performance in freezer warehouses or desert sites, and its 40–80KHz anti-crosstalk technology blocks interference from nearby detectors or EV chargers. A recent deployment at a Middle Eastern logistics park reduced unauthorized access by 40% through real-time directional monitoring. The sensor’s universal 12-24V DC/100-240V AC input supports solar and grid power, while SPDT relay outputs integrate seamlessly with barrier controllers, license plate recognition systems, and IoT platforms for centralized management.
JUTAI prioritizes ease of deployment and compliance: plug-and-play DIN-rail mounting reduces installation time to 15 minutes, and auto-reset functionality ensures uninterrupted operation during voltage fluctuations. Certified for CE, FCC, and RoHS, it meets global safety and environmental standards. Backed by a 5-year warranty and 24/7 technical support, the JUTAI Dual Channel Sensor is the definitive choice for engineers seeking durability, precision, and intelligent barrier control—where cutting-edge direction logic meets industrial resilience.

Feature
- 1. 15-2000 μh detection Range
- The loop detector supports a wide detection range from 15 µH to 2000 µH, accommodating various loop sizes and configurations for versatile application in different traffic detection scenarios.
- The wide detection range enables our loop detector to detect all kinds of vehicles, motorcycles, cars, Ultra long truck, buses and so on
- 2. Compact Side
- The compact and well-engineered housing combines all industry requirements for features and functionality, allowing this detector to be incorporated into any existing traffic detection system.
- 3. Diagnostic Capabilities & LED Indication
- Comprehensive diagnostics capabilities enable accurate diagnosis of loop and installation problems and shows through the LED state, ensuring optimal performance and reducing downtime.
- 4. Selectable Presence Time
- The output of the presence relay can be selected to limit a detect output to a fixed time (greater than 30 minutes) while a vehicle remains on the loop, providing flexibility in traffic management.
- 5. Automatic Sensitivity Boost (ASB)
- This feature reliably detects large truck-trailer combinations and high-bed vehicles by automatically boosting the sensitivity to maximum upon vehicle detection, ensuring accurate identification.
- 6. Automatic Environment Drifting Compensation
- Loop detectors (or other sensors) automatically adjust and calibrate themselves to changes in environmental conditions, maintaining detection accuracy and stability despite varying weather and environmental factors.
- 7. 17 Dip Switch Setting
- The dip swich design on the shell makes the setting of loop detector easier and clearer, which is very user-friendly for users. Users can set all the functions first and then install the loop detector.
- 8. Dual Channels work Cooperatively or Independently
- Dual channel loop detector can be used as two single channel versions, Supports two independent detection channels.
- Also allowing for the simultaneous monitoring of multiple loops, loop detector has the ability to recognize direction in single-channel applications. enhancing the flexibility and accuracy of vehicle detection.
- 9. Anti-crosstalk interference.
- Through the dip Switch, the frequency of the loop detector can be adjusted to prevent crosstalk interference caused by the installation of two loop coils too close.
Connections

Modes Of Operation
The LD-200 series detector may be configured for any one of the following modes:
Presence Mode | Pulse Mode |
AB Logic Presence Mode(Barrier Operation) | AB Logic Pulse Mode(Counting Logic) |
Indicates And Switch
❀Power Led: RED Power LED Indicates “Power ON”
-
CH1 Detecting Led:Continuously On: Indicates vehicle detection.
-
Blinking Slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
-
Blinking Fast: Indicates loop is open circuit or too many twists after the loop.
-
CH2 Detecting Led:Continuously On: Indicates vehicle detection.
-
Blinking Slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
-
Blinking Fast: Indicates loop is open circuit or too many twists after the loop.
❀Sensitivity Selection
-
Sensitivity and frequency of the loop can be adjusted by 7-way dip switch and 10-way dip switch setting.
-
User can select 8 different setting by changing the setting of the dip-switch to different modes as in the dip-switch setting tables below. Dip switch 6, 7 and 8 for CH1 sensitivity selection with 0.8 being the least sensitive and 0.015 being the most sensitive.
-
Dip switch 3, 4 and 5 for CH2 sensitivity selection with 0.8 being the least sensitive and 0.015 being the most sensitive.

❀Switch1=S1:Channel 1 Loop Function Selection (10 Way Dip Switch)

-
(Switch1=S1)D3,D4,D5 and(Switch2=S2)D1,D2 Setting Special Functions(Mode1,2,3 Direction Detection. Mode4,5,6 Normal mode, two loop detection are separated.)



Reset Button: Please note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Loop Installation
The loops are sealed using a “quick-set” black epoxy compound or hot bitumen mastic to blend with the roadway surface.
When installation, please keep the product plug and socket in the vertical direction
Trouble Shooting

Product Series
LD-100 | LD-102 | LD-200 | LD-202 | JTHT-11 |
 Single Channel 100-240 V AC |  Single Channel 12-24 V AC/DC |  Dual Channel 100-240 V AC |  Dual Channel 12-24 V AV/DC |  Loop cable 305 m Teflon coil |
LCR-MT | | | | |
 Multimeter | | | | |